This user guide describes the AD9680/AD9234 evaluation board which provides all of the support circuitry required to operate the ADC in its various modes and configurations. Users wanting to evaluate the single channel AD9690 should utilize/evaluate Channel A on the AD9680-500EBZ, or AD9680-1000EBZ. The application software used to interface with the devices is also described. This user guide wiki applies to the following evaluation boards:
Evaluation Board Part Number | Description | Board Revision |
---|---|---|
AD9680-1250EBZ | Evaluation board for AD9680-1250; Full Bandwidth | 9680CE04B |
AD9680-1000EBZ | Evaluation board for AD9680-1000; Full Bandwidth | 9680CE04B |
AD9680-820EBZ | Evaluation board for AD9680-820; Full Bandwidth | 9680CE04B |
AD9680-500EBZ | Evaluation board for AD9680-500; Full Bandwidth | 9680CE04B |
AD9234-1000EBZ | Evaluation board for AD9234-1000; Full Bandwidth | 9680CE04B |
AD9234-500EBZ | Evaluation board for AD9234-500; Full Bandwidth | 9680CE04B |
AD9680-LF1000EBZ | Evaluation board for AD9680-1000; up to 1GHz Input Bandwidth | 9680CE02B |
AD9680-LF820EBZ | Evaluation board for AD9680-820; up to 1GHz Input Bandwidth | 9680CE02B |
AD9680-LF500EBZ | Evaluation board for AD9680-500; up to 1GHz Input Bandwidth | 9680CE02B |
AD9234-LF1000EBZ | Evaluation board for AD9234-1000; up to 1GHz Input Bandwidth | 9680CE02B |
AD9234-LF500EBZ | Evaluation board for AD9234-500; up to 1GHz Input Bandwidth | 9680CE02B |
The AD9680 and AD9234 data sheets provide additional information and should be consulted when using the evaluation board. All documents and software tools are available at www.analog.com/hsadcevalboard. For additional information or questions, send an email to highspeed.converters@analog.com.
AD9680/AD9234 Evaluation Board
Figure 3 below compares the bandwidth available on the AD9680/AD9234 normal evaluation boards and the “LF” boards
Figure 3. Comparison of Bandwidth on the Normal and the “LF” boards
Typical Measurement Setup
The AD9680-1000EBZ/AD9234-1000EBZ can be evaluated using the ADS7-V2EBZ FPGA data capture boards. Figures 3 and 4 below show the AD9680-1000EBZ/AD9234-1000EBZ connected to the ADS7-V1EBZ and ADS7-V2EBZ respectively.
Figure 3. Evaluation Board Connection—AD9680-1000EBZ/AD9234-1000EBZ (on Left) and ADS7-V1EBZ (on Right)
Please note : ADS7-V1EBZ has been obsoleted and is NOT recommended for new evaluations.
Figure 4. Evaluation Board Connection—AD9680-LF1000EBZ/AD9234-LF1000EBZ (on Left) and ADS7-V2EBZ (on Right)
Features
-
- AD9680-1000EBZ, AD9680-LF1000EBZ
- AD9680-820EBZ, AD9680-LF820EBZ
- AD9680-500EBZ, AD9680-LF500EBZ
- AD9234-1000EBZ, AD9234-LF1000EBZ
- AD9234-500EBZ, AD9234-LF500EBZ
- SPI interface for setup and control
- Wide band Balun driven input for the AD9680-1000EBZ, AD9680-820EBZ, AD9680-500EBZ, AD9234-1000EBZ and AD9234-500EBZ
- Double balun input for AD9680-LF1000EBZ, AD9680-LF820EBZ, AD9680-LF500EBZ, AD9234-LF1000EBZ and AD9234-LF500EBZ
- No external supply needed. Uses 12V-1A and 3.3V-3A supplies from FMC
- VisualAnalog® and SPI controller software interfaces
- On-board Crystal oscillator for AD9680-LF1000EBZ, AD9234-LF1000EBZ, AD9680-500EBZ, AD9234-LF500EBZ
Helpful Documents
- ADS7-V2EBZ evaluation kit (ADS7-V2EBZ)
- AN-905 Application Note, VisualAnalog Converter Evaluation Tool Version 1.0 User Manual
- AN-878 Application Note, High Speed ADC SPI Control Software
- ADI SPI Application Note ADI Serial Control Interface Standard
- AN-835 Application Note, Understanding ADC Testing and Evaluation
Software Needed
Design and Integration Files
- AD9680CE04B schematic, BOM, Gerber files ftp://ftp.analog.com/pub/HSC_ADC_Apps/AD9680CE04B_Design_Support/
- AD9680CE02B schematic, BOM, Gerber files ftp://ftp.analog.com/pub/HSC_ADC_Apps/AD9680CE02B_Design_Support/
Equipment Needed
- Analog signal source and antialiasing filter
- Sample clock source
- 12V, 6.5A switching power supply (such as the SL POWER CENB1080A1251F01 supplied with ADS7-V2EBZ)
- PC running Windows®
- USB 2.0 port
- ADS7-V2EBZ FPGA-based data capture kit
Getting Started
This section provides quick start procedures for using the evaluation board for AD9680 or AD9234.
Configuring the Board
Before using the software for testing, configure the evaluation board as follows:
- Connect the evaluation board to the ADS7-V2EBZ data capture board, as shown in Figure 2.
- Connect one 12V, 6.5A switching power supply (such as the CENB1080A1251F01 supplied) to P4 on the ADS7-V2EBZ board. Connect the Standard-B USB port of the ADS7-V2EBZ board to the PC with the supplied USB cable.
- Turn on the ADS7-V2EBZ.
- The ADS7-V2EBZ will appear in the Device Manager as shown in Figure 3.
Figure 4. Device Manager showing ADS7-V1EBZ
- If the Device Manager does not show the ADS7-V2EBZ listed as shown in Figure 2, unplug all USB devices from the PC, uninstall and re-install SPIController and VisualAnalog and restart the hardware setup from step 1.
- On the ADC evaluation board, provide a clean, low jitter 1GHz clock source to connector J801 and set the amplitude to 14dBm. This is the ADC Sample Clock.
- On the ADC evaluation board, provide a clean, low jitter clock source to connector J804 and set the amplitude to 10dBm. This is the Reference Clock for the gigabit transceivers in the FPGA. The REFCLK frequency can be calculated using the following empirical formulae:
bps/lane, where
(Default Nprime = 16)
- On the ADC evaluation board, use a clean signal generator with low phase noise to provide an input signal for channel A to P200. Use a shielded, RG-58, 50 Ω coaxial cable to connect the signal generator output to the ADC Evaluation Board. For best results, use a narrow-band, band-pass filter with 50 Ω terminations and an appropriate center frequency. (ADI uses TTE, Allen Avionics, and K & L band-pass filters.)
- On the ADC evaluation board, use a clean signal generator with low phase noise to provide an input signal for channel B to P202. Use a shielded, RG-58, 50 Ω coaxial cable to connect the signal generator output to the ADC Evaluation Board. For best results, use a narrow-band, band-pass filter with 50 Ω terminations and an appropriate center frequency. (ADI uses TTE, Allen Avionics, and K & L band-pass filters.)
Visual Analog Setup
- Click Start All Programs Analog Devices VisualAnalog VisualAnalog
- On the VisualAnalog “New Canvas” window, click ADCDualAD9680 or ADCDualAD9234
Figure 5. Selecting the AD9680 canvas
- At this point, VisualAnalog will automatically detect the evaluation board and the FPGA data capture board and ask if it can program the FPGA with the appropriate bin file. This is shown in figure 6. Programming the FPGA will provide power to the evaluation board.
Figure 6. Programming the ADS7-V2EBZ
- If VisualAnalog opens with a collapsed view, click on the “Expand Display” icon (see figure 7)
Figure 7. Expanding Display in VA
- Click the Settings button in the ADC Data Capture block as shown in Figure 8
Figure 8. Changing the ADC Capture Settings
- On the General tab make sure the clock frequency is set to the appropriate sample rate (eg. 1000MHz or 500MHz). The FFT capture length may be changed to 131072 (128k) or 262144 (256k) per channel. The ADs7-V2 FPGA software supports up to 2M FFT capture (1M per channel)
Figure 9. Setting the clock frequency and Capture length
- On the Device tab. Make sure that Enable Alternate REFCLK option is unchecked.
- Click OK
SPIController Setup
- Click Start All Programs Analog Devices SPIController SPIController
- Select the appropriate configuration file when prompted.
- In the Global tab, under the Generic Read/Write section, write 0x81 to register 0x000. This issues a Soft reset for the DUT.
Figure 9. Sending a Soft Reset to the AD9680
- The JESD204B quick configuration and Lane Rate registers are available in the ADCBase3 tab. Set the Lane Rate setting register 0x56E to Maximum Lane Rate. The decision to use Maximum Lane Rate mode or Low Lane Rate mode should be based on the Lane Line Rate that was calculated in Configuring the Board section.
Figure 10. Setting the JESD204B Lane Rate
- Set the JESD204B Quick Configuration register 0x570. For 1000MSPS operation with NO DDCs (Full Bandwidth Mode), the values for L.M.F are 4.2.1
Figure 11. Setting the JESD204B Quick Configuration Register
- After the quick configuration setting is completed, the PLL Lock Detect register 0x56F will read 0x80 to denote a lock. The SPIController interface will show a “1” to denote a lock.
- Toggle the JESD204B link by checking and then unchecking the JESD204B Serial Transmit Power Down box
- Individual Channel control for ADC A and ADC B are done using the Device Index Register (0x008) in the Global tab.
Figure 12. Device Index for ADC Channel A and Channel B
- Under ADC A and ADC B tabs the options for Channel A and B are listed. Default settings have been programmed to ensure optimal performance for the input bandwidth and sample rate. Only the following options need to be operated with:
- Chip Configuration Register (2): This option allows the channel to be powered on
- Buffer Current Setting (18): This option allows the buffer current to change to enable better harmonic performance at different frequencies. At high analog input frequencies, the buffer current may need to be increased to optimize harmonic distortion performance (HD2, HD3). Keep in mind that at high frequencies, the performance is also jitter limited. So increasing the buffer currents may lead to diminishing returns with higher power consumption. Refer to the datasheet to understand the relationship between IAVDD3 and Buffer Current Setting.
- Analog Input Differential Termination (16): This sets the input termination. Recommended settings are 500, 200, 100, 50 ohms. At lower termination settings, the harmonic distortion performance may show improvement, but the analog input signal amplitude will be reduced.
- Input Full Scale Range (25): At high input frequencies, in order to preserve the linearity of the input buffer, it may be beneficial to reduce the input full-scale range in order to get more harmonic distortion performance. This in turn may negatively affect the SNR of the ADC.
Obtaining an FFT
- Click the Run button in VisualAnalog , you should see the captured data similar to the plot shown in Figure 13.
Figure 13. AD9680-1000 FFT at 170MHz Analog Input
- Adjust the amplitude of the input signal so that the fundamental is at the desired level. (Examine the Fund Power reading in the left panel of the VisualAnalog FFT window.)
- To save the FFT plot do the following
- Click on the Float Form button in the FFT window
Figure 14. Floating the FFT window
- Click on File Save Form As button and save it to a location of choice
Figure 15. Saving the FFT
Validating Deterministic Latency Using Subclass 1 Operation
The following .zip files contain the files needed for users to validate subclass 1 operation and observe the latency differences between subclass 0 and subclass 1 operation. The “Validating Subclass 1 Operation of the AD9680” document will guide the user through the necessary steps to perform this validation. SPI Controller scripts for several full bandwidth modes are included for convenience. ad9680_ads7v2_dl_demo.zip spicontroller_scripts_for_dl_demo.zip
Troubleshooting Tips
FFT plot appears abnormal
- If you see a normal noise floor when you disconnect the signal generator from the analog input, be sure you are not overdriving the ADC. Reduce input level if necessary.
- In VisualAnalog, Click on the Settings button in the Input Formatter block. Check that Number Format is set to the correct encoding (twos compliment by default). Repeat for the other channel.
- Issue a Data Path Soft Reset through SPIController Global tab as shown in Figure 16
Figure 16. Issuing a data path soft reset through SPIController
The FFT plot appears normal, but performance is poor.
- Make sure you are using the appropriate band-pass filter on the analog input.
- Make sure the signal generators for the clock and the analog input are clean (low phase noise).
- If you are using non-coherent sampling, change the analog input frequency slightly, or use coherent frequencies.
- Make sure the SPI config file matches the product being evaluated.
The FFT window remains blank after the Run button is clicked
- Make sure the evaluation board is securely connected to the ADS7-V2.
- Make sure the FPGA has been programmed by verifying that the Config DONE LED is illuminated on the ADS7-V2. If this LED is not illuminated reprogram the FPGA through VisualAnalog. If the LED still does not illuminate disconnect the USB and power cord for 15 seconds. Connect again and repeat the ADS7-V2 setup process.
- Make sure the correct FPGA bin file was used to program the FPGA.
- Be sure that the correct sample rate is programmed. Click on the Settings button in the ADC Data Capture block in VisualAnalog, and verify that the Clock Frequency is properly set.
Figure 17. Setting the correct clock frequeency in VisualAnalog
- Ensure that the REFCLOCK is ON and set to the appropriate frequency.
- Restart SPIController.
VisualAnalog indicates that the “FIFO capture timed out” or “FIFO not ready for read back”
- Make sure all power and USB connections are secure.
- Make sure that the REFCLOCK is ON and set to the appropriate frequency.
VisualAnalog displays a blank FFT when the RUN button is clicked
- Ensure that the clock to the ADC is supplied. Using SPIController ADCBase0 tab the status of the clock can be read out. See figure 18.
Figure 18. Clock Detection Status Register
- Ensure that the ADC's PLL is locked by checking the status of the PLL lock detect register 0x56F. This can be done using SPIController.
- AD9680模数转换器英文手册 0次下载
- AD9234 IBIS型号
- AD9680 AMI型号
- 更改AN-710(AD6674/AD9234/AD9680/AD9690 Stratix5-Arria10)
- 评估AD9681模数转换器
- 评估AD9656模数转换器
- 评估AD9683/AD6677模数转换器
- 评估AD9257/AD9637模数转换器
- 软件用户指南-用于评估EasySuite™高速、低功耗模数转换器评估软件
- AD9680 MATLAB ADIsimADC
- AD9680 AMI型号
- AD9680 S参数
- 评估AD9208模数转换器
- AD9680: 14位、1000 MSPS JESD204B双通道模数转换器
- AD9680高速模数转换器的电路原理图合集免费下载 45次下载
- RA6T2的16位模数转换器操作 [13] 运行应用项目 224次阅读
- 模数转换器的威廉希尔官方网站 参数详解 913次阅读
- 模数转换器的工作原理、分类及应用 818次阅读
- RA6T2的16位模数转换器操作 [2] A/D转换器概述 (2) 224次阅读
- RA6T2的16位模数转换器操作 [1] 简介,A/D转换器概述 185次阅读
- ADC模数转换器的延时原理 766次阅读
- 模数转换器损坏该如何处理? 459次阅读
- 串行逐次逼近型模数转换器MAX1132的性能特点及应用 1126次阅读
- 模数转换器分类_模数转换器选型 5572次阅读
- 如何降低模数转换器的性能 3991次阅读
- 关于高速ADC模数转换器精度问题 9446次阅读
- 模数转换器的工作原理与分类特点详解 4452次阅读
- 小白必看:模数转换器应用典型电路设计详细解析 2.2w次阅读
- 模数转换器工作原理、类型及主要威廉希尔官方网站 指标 2w次阅读
- 模数转换器的基本原理及不同类型ADC特点 3.3w次阅读
下载排行
本周
- 1电子电路原理第七版PDF电子教材免费下载
- 0.00 MB | 1491次下载 | 免费
- 2单片机典型实例介绍
- 18.19 MB | 95次下载 | 1 积分
- 3S7-200PLC编程实例详细资料
- 1.17 MB | 27次下载 | 1 积分
- 4笔记本电脑主板的元件识别和讲解说明
- 4.28 MB | 18次下载 | 4 积分
- 5开关电源原理及各功能电路详解
- 0.38 MB | 11次下载 | 免费
- 6100W短波放大电路图
- 0.05 MB | 4次下载 | 3 积分
- 7基于单片机和 SG3525的程控开关电源设计
- 0.23 MB | 4次下载 | 免费
- 8基于AT89C2051/4051单片机编程器的实验
- 0.11 MB | 4次下载 | 免费
本月
- 1OrCAD10.5下载OrCAD10.5中文版软件
- 0.00 MB | 234313次下载 | 免费
- 2PADS 9.0 2009最新版 -下载
- 0.00 MB | 66304次下载 | 免费
- 3protel99下载protel99软件下载(中文版)
- 0.00 MB | 51209次下载 | 免费
- 4LabView 8.0 专业版下载 (3CD完整版)
- 0.00 MB | 51043次下载 | 免费
- 5555集成电路应用800例(新编版)
- 0.00 MB | 33562次下载 | 免费
- 6接口电路图大全
- 未知 | 30320次下载 | 免费
- 7Multisim 10下载Multisim 10 中文版
- 0.00 MB | 28588次下载 | 免费
- 8开关电源设计实例指南
- 未知 | 21539次下载 | 免费
总榜
- 1matlab软件下载入口
- 未知 | 935053次下载 | 免费
- 2protel99se软件下载(可英文版转中文版)
- 78.1 MB | 537793次下载 | 免费
- 3MATLAB 7.1 下载 (含软件介绍)
- 未知 | 420026次下载 | 免费
- 4OrCAD10.5下载OrCAD10.5中文版软件
- 0.00 MB | 234313次下载 | 免费
- 5Altium DXP2002下载入口
- 未知 | 233046次下载 | 免费
- 6电路仿真软件multisim 10.0免费下载
- 340992 | 191183次下载 | 免费
- 7十天学会AVR单片机与C语言视频教程 下载
- 158M | 183277次下载 | 免费
- 8proe5.0野火版下载(中文版免费下载)
- 未知 | 138039次下载 | 免费
评论
查看更多